| SAT-ACO
Series Intellectualized AC Load |
|
|
| |
 |
| |
◆ Functions & Features:
◆Set/adjust discharging power according to performance
parameters and detection requirements.
◆Set discharging time,timing to automatic shut-off load,discharge
off and alarm operator.
◆Set load voltage,over/under voltage and over current
protection threshold value,it can shut off load,terminate
discharging and alarm user automatically.
◆Set storage datasheet recording period optionally which
must be more than the minimum period 6Seconds.
◆Large screen LCD display,friendly interface,English menu,display
discharge power,time,power consumption,every phase load
voltage,current,frequency and inner temperature information
real timly.
◆Parallel operation function to carry out multi sets load
operation by RS 485 communication.
◆Readjust discharg paremeters during discharging process.
◆Built-in storage function,save 10 groups of test data,which
can be inquired,deleted and put into flash disk.
◆Start/stop discharging control by Serial port,and detect
data real time operation etc;The storage data can be uploaded
to PC by serial port or flash disk,and the upper computer’s
software can analyze data and pattern and print report
etc.
◆Thernal protetion function,it can turn off load,terminate
discharging and alarm automatically when over temperature.
◆Power Fail Recovery function.
◆ Set at most 10 groups power,load process automatically
according to the setting power and operation time after
being turned on.
|
| ◆ Technical Parameters: |
| Condition of Circumstance |
Working Temperature:(-20~55)℃
Storage Temperature:(-45~70)℃
Relative humidity:90%(40±2℃)
Atmospheric pressure:(70~106)kPa |
| External Dimensions(mm) |
670×620×905mm |
| Weight |
90kg |
| Working Voltage |
Single-phase AC220V±10%,50Hz |
| Load voltage |
Three-phase AC380V、Single-phase AC220V |
| Operating power |
Stand-alone:Max 100KW(Three-phase 380V)
Max 30KW(Singly-phase 220V)
Parallel Operation:Sum of all stand-alones’ max
power |
| Discharging Time |
0~(99 hours and 59 minutes)Contunuously Adjustable |
| Tempearature alarm & Threshold
Value |
75℃ |
| Quantity of Parallel operation |
1~99 sets |
| Recording Period |
6~999 Seconds |
| Voltage measurement range |
AC 0~450V, Display Resolution:0.1V,Precision:±5‰ |
| Current measurement range |
AC 0~200A, Display Resolution:0.1A,Precision:±1% |
| Frequency measurement range |
40~60 Hz, Display Resolution:0.1Hz,Precision:±2‰ |
| Power measurment range |
0~100 kW, Display resolution:0.1kW,Precision:±1% |
| Temperature measurement range |
-20~100℃,Display resolution:1℃,precision:±1℃ |
| Cooling mode |
FCT(Fan control Temperature) |
| Communication Mode |
RS232,RS485 and USB communication |
| Display mode |
LCD with high brightness and large screen |
| MTTF |
≥50000h |
|
|
| |
|
|