  • Description:
  • Test discharge three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time, energies of generators and UPS.
    Set/adjust discharging power according to performance parameters and detection requirements
    Set discharging time, timing to automatic shut-off load, discharge off and alarm operator
    Set over/under voltage protection threshold value, it can shut off load, terminate discharging and alarm user automatically.
    Large LCD screen, friendly interface. English menu and easy operation.

  • Contact Now
  • Google+ Pinterest LinkedIn Facebook Twitter Addthis
  • small SAT-ACO380 AC Load image
  • small SAT-ACO380 AC Load image
  • small SAT-ACO380 AC Load image
  • small SAT-ACO380 AC Load image

Tel: (+86) 29 65660081

E-mail: sales@aitelong.com

  • Description
  • Specification
  • Packing list
  • Datasheet download

Functions & Features
◆Test discharge three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time, energies of generators and UPS.
◆Set/adjust discharging power according to performance parameters and detection requirements
◆Set discharging time, timing to automatic shut-off load, discharge off and alarm operator
◆Set over/under voltage protection threshold value, it can shut off load, terminate discharging and alarm user automatically.
◆Large LCD screen, friendly interface. English menu and easy operation.
◆Parallel operation function to carry out multi sets load operation by RS 485 communication
◆Built-in storage function, save 30 groups of test data, which can be inquired, deleted and put into SD card.
◆Start/stop discharging control by Serial port, and detect data real time operation etc; The storage data can be uploaded to PC by serial port or SD card, and the upper computer’s software can analyze data and pattern and print report etc.
◆Overheating and over current protection function, it can turn off load, terminate discharging and alarm automatically when over temperature and over current.
◆Set at most 5 groups power, load process automatically according to the setting power and operation time after being turned on.

Mode

ACO 380/02

ACO 380/04

ACO 380/10

Working environment

Working Temperature: (-20~55)℃        

Storage Temperature: (-45~75)℃ 

Relative humidity: 90%(40±2℃) 

Atmospheric pressure: (70~106)KPa

Working power supply 

Single-phase AC220V±10, 50Hz

Load voltage

Three-phase AC380V, Single-phase AC220V

Operating power

Stand-alone: Max 20KW
(Three-phase 380V) 

Max 6KW
(Singly-phase 220V) 

Stand-alone: Max 40KW
(Three-phase 380V) 

Max 13KW
(Singly-phase 220V)

Stand-alone: Max 100KW
 (Three-phase 380V) 

Max 30KW (Singly-phase 220V)

Cooling mode

FCT(Fan control Temperature)

Communication Mode

RS232, RS485 and SD card 

Display mode

8 inch TFT 

Voltage measurement range

AC 0~450V, Display
Resolution: 0.1V,
Precision: ±0.5%

Current measurement range

AC 0~100A, Display
Resolution: 0.1A,
 Precision: ±0.5

AC 0~150A, Display
Resolution: 0.1A,
 Precision: ±0.5

AC 0~300A, Display
 Resolution: 0.1A,
Precision: ±0.5

Frequency measurement range

40~60 Hz, Display
Resolution: 0.01Hz,
Precision: ±0.2%

Power measurement range

0~20 KVA, Display
Resolution: 0.1KVA,
Precision: ±1

0~40 KVA, Display
Resolution: 0.1KVA,
 Precision: ±1

0~100 KVA, Display
Resolution: 0.1KVA,
 Precision: ±1

Power factor measurement range

0.001~1.000, Display Resolution: 0.001, Precision: ±0.5%

Discharging Time

(0~19 hours and 59 minutes) adjustable continuously 

Quantity of Parallel operation

1~99 sets 

Recording Period

6~999 Seconds 

Temperature measurement range

-20~100℃,Display resolution: 1℃, precision:±1℃ 

Insulating strength

Input≥AC1500V 

Output≥AC500V 

MTTF

≥50000h

Dimensions(mm)

420×500×750mm

680×600×900mm

680×600×900mm

Weight

30kg

50kg

70kg

Mode

ACO 380/20

Working environment

Working Temperature: (-20~55)℃        

Storage Temperature: (-45~75)℃ 

Relative humidity: 90%(40±2℃) 

Atmospheric pressure: (70~106)KPa

Working power supply 

Single-phase AC220V±10, 50Hz

Load voltage

Three-phase AC380V, Single-phase AC220V

Operating power

Stand-alone: Max 200KW (Three-phase 380V) 

          Max 66KW (Singly-phase 220V)

Cooling mode

FCT(Fan control Temperature)

Communication Mode

RS232, RS485 and SD card 

Display mode

8 inch TFT 

Voltage measurement range

AC 0~450V, Display Resolution: 0.1V, Precision: ±0.5%

Current measurement range

AC 0~400A, Display Resolution: 0.1A, Precision: ±0.5

Frequency measurement range

40~60 Hz, Display Resolution: 0.01Hz, Precision: ±0.2%

Power measurement range

0~200 KVA, Display Resolution: 0.1KVA, Precision: ±1

Power factor measurement range

0.001~1.000, Display Resolution: 0.001, Precision: ±0.5%

Discharging Time

(0~19 hours and 59 minutes) adjustable continuously 

Quantity of Parallel operation

1~99 sets

Recording Period

6~999 Seconds

Temperature measurement range

-20~100℃,Display resolution: 1℃, precision:±1℃

Insulating strength

Input≥AC1500V

Output≥AC500V

MTTF

≥50000h

Dimensions(mm)

1300×600×900mm

Weight

150kg

Mode

ACO 380/50

Working environment

Working Temperature: (-20~55)℃        

Storage Temperature: (-45~75)℃ 

Relative humidity: 90%(40±2℃) 

Atmospheric pressure: (70~106)KPa

Working power supply 

Single-phase AC220V±10, 50Hz

Load voltage

Three-phase AC380V, Single-phase AC220V

Operating power

Stand-alone: Max 500KW (Three-phase 380V) 

          Max 160KW (Singly-phase 220V)

Cooling mode

FCT(Fan control Temperature)

Communication Mode

RS232, RS485 and SD card 

Display mode

8 inch TFT 

Voltage measurement range

AC 0~450V, Display Resolution: 0.1V, Precision: ±0.5%

Current measurement range

AC 0~400A, Display Resolution: 0.1A, Precision: ±0.5

Frequency measurement range

40~60 Hz, Display Resolution: 0.01Hz, Precision: ±0.2%

Power measurement range

0~200 KVA, Display Resolution: 0.1KVA, Precision: ±1

Power factor measurement range

0.001~1.000, Display Resolution: 0.001, Precision: ±0.5%

Discharging Time

(0~19 hours and 59 minutes) adjustable continuously 

Quantity of Parallel operation

1~99 sets

Recording Period

6~999 Seconds

Temperature measurement range

-20~100℃,Display resolution: 1℃, precision:±1℃

Insulating strength

Input≥AC1500V

Output≥AC500V

MTTF

≥50000h

Dimensions(mm)

1600×1200×1650mm

Weight

350kg

It is only for reference. The actual accessories and quantity are according to demand.

No.

Description

Qty

Remark

1

SAT-ACO 380/04 AC Load

1pcs

Main unit

2

230V Power Cord

1pcs

 

3

AC input cable

4pcs

 

4

RS-232 Convert Cable

pcs

 

5

Software Disc

pcs

 

6

User’s Manual

pcs

 

7

Certificates/ Warranty Card

pcs

 

8

SD Card

1set

Including the Card Reader

9

Packing List

pcs

 


http://www.aitelong.com/pdf/SAT-ACO-380-AC Load.pdf

Online Inquiry

Please feel free to give your inquiry in the form below. We will reply you in 24 hours.

Welcome you to visit Aitelong, please SIGN IN to download documents. Or take one minute to Creat an account as a menber.
USER LOGIN

  •  

Having trouble signing in?

Creat an account