AITELONG Products

CA-17 High Precision Cleaver

CA-17 High Precision Cleaver
CA-17 High Precision CleaverCA-17 High Precision CleaverCA-17 High Precision CleaverCA-17 High Precision CleaverCA-17 High Precision CleaverCA-17 High Precision Cleaver

CA-17

CA-17 High Precision Cleaver

High Precision cleaver, applied to Single Fiber (250µm,900µm, 3.0mm, indoor fiber) and 2-12 cores Ribbon Fiber

Contact Aitelong →
Download Product Datasheet ↓

Weight & Dimension

1513572778

Dimension: 63(W)*75(D)*62(H)mm

Weight:400g(0.88lb)

User Manual

1. Key Features

  • High Precision cleaver, applied to Single Fiber (250µm,900µm, 3.0mm, indoor fiber) and 2-12 cores Ribbon Fiber
  • Total 24 cleave blade end faces, and each blade end face can be used 3000 times, can totally use 72000 times.
  • Average cleave angle less than 0.5°.
  • Easily operate, both on hand or desk, and right or left hand.
  • Easily load the fiber, the cleaver can auto-reset, improve the work

9C80983A8C24789F1D0B0A26B67D1CFA

Cleaver

1 pc

Blade type

20*4*3

(12 end faces)

Warranty Card

1 pc

1.5mm Hexagon Wrench

1 pc

2.5mm Hexagon Wrench

1 pc

Package box

1 pc

Additional

Fiber Fixture

FH-SOC(for hot-melt )

FH-12R(for 12 cores)

efficiency.

  • Artful fiber clamp design, and prevent the fiber damage caused by

secondary cutting.

High intensity and fashion appearance.

  • Anti-skid design for bottom, to make sure cleaver stable and safe when working.

Package

2. Structure

4. Blade Adjustment

After many times of cleave, a symptom that the fiber can’t be cleaved, cracks appear in end face, when it continued to happen, need to adjust the position of blade, then can use the new side of blade.

1. Use a screwdriver to loosen the screw and rotate the blade to a new end face (Use the cotton swab to press the blade flank or front, and push the blade outwards to make rotate operation easier.)

After finishing rotating, tighten the blade fixed screw

Reference: Tighten the screw properly, about 0.98Nm (10 kgf.cm)

3. Specification

Model

CA-17 Single Fiber & Ribbon Fiber Cleaver

Cladding Diameter

125µm

Cutting Length

Single Fiber: 8—20mm/ Ribbon fiber:10mm

Applicable Fiber

Single Fiber:250µm,900µm, 3.0mm/Ribbon Fiber: 2—12 core ribbon cable

Average Cutting Angle

Less than 0.5°

Blade Life

72000 times(1000Times×24End face×3Height)

Operation Steps

2 steps

Reset Function

Blade reset

Fiber Fixture

Single fiber: Universal fiber fixture/ Ribbon fiber: Replaceable ribbon fiber fixture

▪ Do not rotate the blade with hands.

▪ Do not rotate the blade with metallic tweezers.

▪ The blade will be damaged if use metallic tweezers

▪ Do not fix the blade too tightly, to avoid the screw damage

u=1323306242,1670909174&fm=27&gp=0

Blade adjust method

After many times of cleave, a symptom that the fiber can’t be cleaved, cracks appear in end face, when it continued to happen, need to adjust the position of blade, then can use the new side of blade. (Reference) 3000 fiber per position (3 times of height)

2. Try to cleave the fiber 1~3 times, and place it on fusion splice V-groove and judge the cleave quality by screen. If the end face is unqualified, please

adjust the blade height.

7. Troubleshooting

5. Blade Height Adjustment

1. If have cleaver has a fiber off-cut collector, take out it at first.

2. Loosen the 2 fixed screw, and then loosen the screw which is fixed the blade

3. Place a mechanical pencil lead a light stick on clamp. Slide the blade carriage back and turn the blade height adjustment screw. The point where the lead barely touches the edge of the blade is a reference point (0µm)

Cutting defects may be caused by the following:

(A) The fiber is placed obliquely

Method: Make sure that the fiber is placed straight in the cleaver.

(B) The blade height is too high.

Method: Adjust the blade height.

(C) Dust or dirt remains on the clamp.

Method: Clean the clamp.

(D) Dust or dirt remains on the blade

Method: Clean the blade.

(E) Dust or dirt remains on the fiber.

Method: Remove the fiber coating and clean the bare fiber again.

Please contact our maintenance service center if it still happen

6. CA-17 Cleaver Testing Analysis

u=1323306242,1670909174&fm=27&gp=0

▪ Dust or fragment on the blade edge or the clamp might

cause loss of cleaving performance or poor quality of fiber end face.

▪ Do not clean them with any other kind of chemicals.

To keep the performance of the cleaver, cleaning after use it, with the cotton swab moistened with isopropyl alcohol. Wipe the blade, fiber clamp and pillow block.

8. Cleaning Method

Related Products

Explore the Same Product Family

Seris Cleavers and Stripper
Fiber Cleavers

Seris Cleavers and Stripper

CS-21 Optical Fiber Cleaver with Thermal Stripper Key features l 2-in-1 multifunction cleaver can operation fiber cutting and thermal stripping by only one machine l CNC machining with all mental machine body, fine workmanshi...